WatchdogCP RMUvi Features
Remote Rectifier Monitor
NTG's Simplest and Most Cost Effective Rectifier Monitor
The NTG RMUvi remote monitor is a compact, easily installed cathodic protection
rectifier monitor that provides reliable:
- Readings of Rectifier volts and amps output
- Alarms when volts or amps drop below or go above programmable alarm limits
- Indication of power loss or power restoration to rectifier
WatchdogCP RMUvi Benefits
- Eliminate travel to sites to perform rectifier readings
- Better access and more data allows improved management
of pipeline integrity
- Maintain a reliable history of rectifier data
- Expandable to monitor other pipeline assets and processes
(valve position, pressure, flow, etc.)
- Low monthly messaging costs
Reliable Operation in a Harsh Environment
Packaged in a rugged ABS enclosure, the RMUvi is designed to handle the harsh pipeline
field environment. Its measurement circuits are relay isolated from the rectifier,
structure, and ground bed, except when briefly connecting in order to take a reading.
This dramatically reduces its vulnerability to lightning damage.
When properly installed, it is impervious to precipitation and harsh weather. Small,
sealed, and unobtrusive, the RMUvi quietly does its job for years, with no maintenance
required. The digital cellular antenna is built right into the unit.
Data is available around the clock from NTG's secure Pipeline Watchdog secure website.
After securely logging in, a user can see, at a glance, the reading history and
status of all NTG RMUs within their group. Reports can be run immediately or scheduled
for monthly email delivery. They are easily imported into all popular CPDM software,
including Bass-Trigon, or they can be printed for filing.
RMUvi Technical Specifications *
Physical:
- 10" high x 5" diameter (25 cm X 13
cm)
Mounting:
- 3" (8 cm) Test Station Riser or optional
Right Angle Bracket
Operating Environment:
- Temperature: -22° to + 158° F (-30°
to + 70° C)
Humidity: 0 - 95%, non-condensing
Power requirement:
- 8 - 40 Vdc or 6 - 30 Vac (recommend
powering from rectifier secondary transformer taps)
Internal backup battery:
- NiCad battery - internally recharged.
10 hour operation after power loss.
Measurement Inputs:
- Channel 1 - rectifier volts: 0 - 100
Vdc +/- 0.5% Input impedance: > 1 MOhm
Channel 2 - rectifier amps: 0 - 100 mV +/- 0.5% Input impedance: > 20kOhm
Digital Input:
- Dry relay contact closure (switches
when resistance goes below 500
Also interfaces to optional AC Voltage Probe (p/n NTG-01-3340-00)
Lightning protection:
- Relay isolated from structure to 1500V,
except during reads (99.8% of time)
MOV protection on each input circuit
Communications:
- GSM Digital cellular using SMS OR Skywave
Inmarsat D+ satellite - clear view of sky to SE or SW required
* Specification subject to change without notice
Ordering Information
WatchdogCP RMUvi:
- GSM Cellular: NTG-01-3310-GS
- Inmarsat D+: NTG-01-3310-ST
|
Product Model Numbers
NTG-01-3310-GS
Pipeline WatchdogCP 2-Channel RMUvi GSM Cellular
NTG-01-3310-ST
Pipeline WatchdogCP 2-Channel RMUvi Monitor Inmarsat D+ satellite
WatchdogCP RMUvi Features
- Automatically report Volts, Amps, and power status
- Equipment failure alarms sent by email and/or text message,
with automatic return-to-normal reports
- Website delivers automated rectifier data reports, in
selectable format for easy import into popular CPDM software (Bass-Trigon, ProActive,
Paradigm, .XLS, .CSV, .XML, etc.)
- All configurable parameters (alarm limits, reporting
schedule) are delivered from the website to the RMU 'over-the-air' - no need to
travel to site with laptop/PDA
- Poll for readings from the NTG Pipeline Watchdog website
in real-time.
- AC power detection detects presence or absence of AC
power to the rectifier
- Simple installation with minimum wiring
- GSM Cellular or Inmarsat D+ Satellite communication
for worldwide deployment
- Rugged, reliable operation in harsh environments
|